diff options
author | Michael Vorobiov <mvorobiov@wm.edu> | 2024-11-05 16:23:42 -0500 |
---|---|---|
committer | Michael Vorobiov <mvorobiov@wm.edu> | 2024-11-05 16:23:42 -0500 |
commit | 1ef08671d000dec11e81467e8c9b3765fd155233 (patch) | |
tree | 12ab389477dc0606bf53a3c061a5727699ab3c39 /run.py | |
parent | 30343811e779792a51275891bb10300525d11e7b (diff) | |
download | qolab-1ef08671d000dec11e81467e8c9b3765fd155233.tar.gz qolab-1ef08671d000dec11e81467e8c9b3765fd155233.zip |
updated run.py script (vscode specific)
Diffstat (limited to 'run.py')
-rw-r--r-- | run.py | 39 |
1 files changed, 29 insertions, 10 deletions
@@ -2,6 +2,8 @@ from qolab.hardware.multimeter.hp3457a import HP3457A from qolab.hardware.multimeter.bk_5491 import BK_5491 from qolab.hardware.multimeter.hp_34401 import HP_34401 from qolab.hardware.vacuum_gauge.mks390 import MKS390 +from qolab.hardware.power_supply.psw25045 import PSW25045 + from qolab.hardware.scope.sds800xhd import SDS800XHD @@ -11,28 +13,42 @@ import pyvisa if __name__ == "__main__": import matplotlib as mpl import matplotlib.pyplot as plt + import time + + #mpl.style.use('custom-style') rm = pyvisa.ResourceManager() - instruments_list = rm.list_resources() + address_dict = { + 'scope': 'TCPIP0::192.168.110.191::inst0::INSTR', + 'dmm_hpa': 'visa://192.168.194.15/GPIB1::22::INSTR', + 'dmm_hp': 'visa://192.168.194.15/ASRL9::INSTR', + 'dmm_bk': 'visa://192.168.194.15/ASRL12::INSTR', + 'vacgauge': 'visa://192.168.194.15/ASRL13::INSTR', + 'psu_anode': 'visa://192.168.194.15/ASRL10::INSTR' + } #---------------------------------------------- # Open visa resources and initialize intruments dmm_hpa = HP3457A( - rm.open_resource(instruments_list[6]) + rm.open_resource(address_dict['dmm_hpa']) ) dmm_bk = BK_5491( - rm.open_resource(instruments_list[4]) + rm.open_resource(address_dict['dmm_bk']) ) dmm_hp = HP_34401( - rm.open_resource(instruments_list[3]) + rm.open_resource(address_dict['dmm_hp']) ) scope = SDS800XHD( - rm.open_resource(instruments_list[8]) + rm.open_resource(address_dict['scope']) ) gauge = MKS390( - rm.open_resource(instruments_list[5]) + rm.open_resource(address_dict['vacgauge']) + ) + + psu_anode = PSW25045( + rm.open_resource(address_dict['psu_anode']) ) #----------------------------------------------- @@ -42,10 +58,13 @@ if __name__ == "__main__": print(f'BK5491 reading: {dmm_bk.getAdc()}') print(f'HP34401 reading: {dmm_hp.getAdc()}') print(f'MKS390 reading: {gauge.get_pressure()}') - print(f'IG status: {gauge.get_ignition_status()}') - gauge.enable_ignition(False) - print(f'IG status: {gauge.get_ignition_status()}') - trace = scope.getTrace(5) + print(psu_anode.get_idn()) + psu_anode.set_voltage(5) + psu_anode.enable_output(True) + time.sleep(20) + psu_anode.enable_output(False) + + trace = scope.getTrace(4) trace.plot() plt.show()
\ No newline at end of file |