1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
|
import logging
# this should be done before justpy is called or log formatter does not work
logging.basicConfig(format='%(asctime)s %(levelname)8s %(name)s: %(message)s', datefmt='%m/%d/%Y %H:%M:%S')
# import justpy as jp
import pyvisa
import numpy as np
import matplotlib as mpl
import matplotlib.pyplot as plt
import qolab.tsdb as tsdb
import asyncio
import time
import qolab.gui.web as gui
from qolab.hardware import BasicInstrument
from qolab.hardware.scope import SDS1104X
from qolab.hardware.rf_generator import AgilentE8257D
from qolab.hardware.lockin import SRS_SR865A
from qolab.feedback import PID
from qolab.data import TraceSetSameX, TraceXY, Trace
from qolab.hardware.i_server import I800
l = logging.getLogger('qolab.gui.web')
l.setLevel(logging.INFO)
l = logging.getLogger('qolab.tsdb')
l.setLevel(logging.INFO)
logger = logging.getLogger('Magnetometer')
logger.setLevel(logging.INFO)
def getConfig(apparatus):
config = apparatus.config.copy()
ai = apparatus.instruments
for n, i in ai.items():
config[n]=i.getConfig()
return config
class Apparatus(BasicInstrument):
def __init__(self, *args, **kwds):
super().__init__(*args, **kwds)
self.setLockinSlope(0)
@BasicInstrument.tsdb_append
def getBCurrent(self):
scope = self.instruments['scope.monitor']
ch=scope.getTrace(2, decimate=False)
bCurrent = np.mean(ch.y.values); # mV -> mA
return bCurrent
def getErrAndEit(self):
scope = self.instruments['scope.feedback']
# we need to freeze scope since this two values are taken on the same scope
trg_mode = scope.getTriggerMode()
scope.setTriggerMode('STOP')
err = self.getErr()
eit = self.getEIT()
scope.setTriggerMode(trg_mode)
return(err,eit)
@BasicInstrument.tsdb_append
def getErr(self):
scope = self.instruments['scope.feedback']
ch1=scope.getTrace(1, decimate=False)
err = np.mean(ch1.y.values)
return err
@BasicInstrument.tsdb_append
def getEIT(self):
scope = self.instruments['scope.feedback']
ch3=scope.getTrace(3, decimate=False)
eit = np.mean(ch3.y.values)
return eit
@BasicInstrument.tsdb_append
def setFeefback(self, val):
freq0 = self.getRFreq()
self.setRFreq(freq0+val)
@BasicInstrument.tsdb_append
def getRFreq(self):
rfgen = self.instruments['rfgen']
return rfgen.getFreqFixed()
@BasicInstrument.tsdb_append
def setRFreq(self,val):
rfgen = self.instruments['rfgen']
rfgen.setFreqFixed(val)
@BasicInstrument.tsdb_append
def getRFAmplitude(self):
rfgen = self.instruments['rfgen']
return rfgen.getRFAmplitude()
@BasicInstrument.tsdb_append
def setRFAmplitude(self, val):
rfgen = self.instruments['rfgen']
return rfgen.setRFAmplitude(val)
@BasicInstrument.tsdb_append
def setLockinSlope(self, val):
self.lockin_slope=val
if __name__ == '__main__':
# TSDB logger setting
tsdb_client = tsdb.Client('influx', 'http://lumus.physics.wm.edu:8428', database='qolab')
tsdb_ingester = tsdb.Ingester(tsdb_client, batch=11, measurement_prefix='VAMPIRE.HighPower')
# creating Apparatus with all instruments to be logged
apparatus = Apparatus(tsdb_ingester=tsdb_ingester, device_nickname='magnetometer',)
apparatus.config['Device type'] = 'QOL VAMPIRE HighPower magnetometer'
apparatus.config['Device model'] = 'v0.1'
apparatus.config['FnamePrefix'] = 'magnetometer_eit'
apparatus.config['SavePath'] = '/mnt/qol_grp_data/data.VAMPIRE.HighPower'
app_nickname=apparatus.config['DeviceNickname']
logger.info("Accessing hardware")
rm = pyvisa.ResourceManager()
instr_scope=rm.open_resource('TCPIP::192.168.0.61::INSTR')
scope_fdbk = SDS1104X(instr_scope, device_nickname='.'.join([app_nickname, 'scope.feedback']), tsdb_ingester=tsdb_ingester)
instr_scope=rm.open_resource('TCPIP::192.168.0.62::INSTR')
scope_mon = SDS1104X(instr_scope, device_nickname='.'.join([app_nickname, 'scope.monitor']), tsdb_ingester=tsdb_ingester)
instr_rfgen=rm.open_resource('TCPIP::192.168.0.114::INSTR')
rfgen = AgilentE8257D(instr_rfgen, device_nickname='.'.join([app_nickname, 'rfgen']), tsdb_ingester=tsdb_ingester)
instr_lockin=rm.open_resource('TCPIP::192.168.0.51::INSTR')
lockin = SRS_SR865A(instr_lockin, device_nickname='.'.join([app_nickname, 'lockin']), tsdb_ingester=tsdb_ingester)
# adding instruments to apparatus
apparatus.instruments={}
ai = apparatus.instruments
ai['rfgen'] = rfgen
ai['lockin'] = lockin
ai['cellTemperatureController'] = I800(device_nickname='.'.join([app_nickname, 'cellTemperatureController']), tsdb_ingester=tsdb_ingester)
ai['scope.feedback'] = scope_fdbk
scope_fdbk.config['SavePath'] = '/mnt/qol_grp_data/data.VAMPIRE.HighPower'
scope_fdbk.config['FnamePrefix'] = 'scope_eit'
# scope_fdbk.setRoll(False)
# scope_fdbk.setRun(True)
# scope_fdbk.setTimePerDiv(0.0005)
# scope_fdbk.setChanVoltsPerDiv(1, 0.02)
# scope_fdbk.setChanVoltsPerDiv(3, 0.02)
ai['scope.monitor'] = scope_mon
# scope_mon.setRoll(False)
# scope_mon.setRun(True)
# scope_mon.setTimePerDiv(0.0005)
# scope_mon.setChanVoltsPerDiv(2, 0.002)
# scope_mon.setChanVoltageOffset(2, -0.0726)
# if we want to save new set of traces repeat this two commands
scope_fdbk.config['tags'] = {}
scope_fdbk.config['tags']['apparatus']=getConfig(apparatus)
scope_fdbk.save( maxRequiredPoints=1000 )
|