1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
|
import logging
# this should be done before justpy is called or log formatter does not work
logging.basicConfig(format='%(asctime)s %(levelname)8s %(name)s: %(message)s', datefmt='%m/%d/%Y %H:%M:%S')
import pyvisa
import numpy as np
import platform
import time
from tqdm import tqdm as pbar
from qolab.hardware import BasicInstrument
from qolab.data import TraceSetSameX, TraceXY, Trace
from qolab.hardware.rf_generator import QOL_LMX2487
from qolab.hardware.daq import LabJackUE9
from qolab.hardware.power_supply.keysight_e3612a import KeysightE3612A
import qolab.tsdb as tsdb
l = logging.getLogger('qolab.tsdb')
l.setLevel(logging.INFO)
logger = logging.getLogger('Magnetometer')
logger.setLevel(logging.INFO)
def getConfig(apparatus):
config = apparatus.config.copy()
ai = apparatus.instruments
for n, i in ai.items():
config[n]=i.getConfig()
return config
class Apparatus(BasicInstrument):
def __init__(self, *args, **kwds):
super().__init__(*args, **kwds)
def getConfig(self):
config = self.config.copy()
ai = self.instruments
for n, i in ai.items():
config[n]=i.getConfig()
return config
# TSDB logger setting
tsdb_client = tsdb.Client('influx', 'http://lumus.physics.wm.edu:8428', database='qolab')
tsdb_ingester = tsdb.Ingester(tsdb_client, batch=11, measurement_prefix='VAMPIRE.VICSEL')
# creating Apparatus with all instruments to be logged
app_nickname = 'magnetometer'
apparatus = Apparatus(tsdb_ingester=tsdb_ingester, device_nickname=app_nickname,)
apparatus.config['Device type'] = 'QOL VAMPIRE VICSEL magnetometer'
apparatus.config['Device model'] = 'v0.1'
apparatus.config['FnamePrefix'] = 'magnetometer_eit'
# apparatus.config['SavePath'] = '/mnt/qol_grp_data/data.VAMPIRE'
apparatus.config['SavePath'] = './data'
logger.info("Accessing hardware")
rm = pyvisa.ResourceManager()
instr=rm.open_resource('USB0::10893::4354::MY61001869::0::INSTR')
ps = KeysightE3612A(instr, device_nickname='.'.join([app_nickname, 'coil_driver']), tsdb_ingester=tsdb_ingester)
if platform.system() == 'Linux':
rfgen_port='/dev/ttyUSB0'
else:
rfgen_port='COM4'
rfgen = QOL_LMX2487(port=rfgen_port, speed=115200, timeout=1, device_nickname='.'.join([app_nickname, 'rfgen']), tsdb_ingester=tsdb_ingester)
daq = LabJackUE9(device_nickname='.'.join([app_nickname, 'daq']), tsdb_ingester=tsdb_ingester)
logger.info("Adding instruments to apparatus")
apparatus.instruments={}
ai = apparatus.instruments
ai['rfgen'] = rfgen
ai['daq'] = daq
ai['coil_driver'] = ps
logger.info('Setting magnetic field coils currents')
"""
Rough magnetic field calibration of the 3 axes coils
- Ch1: 70mA -> 650 kHz shift for delta m = 2
- Ch2: 70mA -> 700 kHz shift for delta m = 2
- Ch2: 70mA -> 659 kHz shift for delta m = 2
"""
ps.setChanIout_mA(1, 70)
ps.setChanIout_mA(2, 0)
ps.setChanIout_mA(3, 0)
logger.info('Done setting magnetic field coils currents')
def eitSweep(central_frequency, frequency_span, Np, Nsweeps=1):
frList = np.linspace(central_frequency-frequency_span/2, central_frequency+frequency_span/2, Np)
trFreq=Trace('Frequency')
trFreq.config['unit']='Hz'
trTransmission=Trace('Transmission')
trTransmission.config['unit']='Arb. Unit'
trLockin=Trace('Lockin')
trLockin.config['unit']='V'
trEIT = TraceSetSameX('EIT')
for sw in pbar(range(1,Nsweeps+1), desc="Sweep"):
for fr in pbar(frList, desc="Freq Scan"):
rfgen.setFreqFixed(float(fr))
time.sleep(dwellTime)
transmission = daq.getAIN(0)
lockin = daq.getAIN(1)
trFreq.addPoint(fr)
trTransmission.addPoint(transmission)
trLockin.addPoint(lockin)
# trFreq.values = trFreq.values - central_frequency
trEIT.addTraceX(trFreq)
trEIT.addTrace(trTransmission)
trEIT.addTrace(trLockin)
trEIT.config['tags']['apparatus']=apparatus.getConfig()
tsdb_ingester.commit()
return trEIT
def eitVsCurrent(ch=1):
curList = [20, 30, 40, 50, 60, 70, 80, 90, 100, 110]
ps.setChanIout_mA(1, 0)
ps.setChanIout_mA(2, 0)
ps.setChanIout_mA(3, 0)
for current in curList:
logger.info(f'Preparing data for {current=} in {ch=} ready')
ps.setChanIout_mA(ch, current)
trEIT = eitSweep(central_frequency, frequency_span, Np, Nsweeps=Nsweeps)
trEIT.plot()
fn = apparatus.getNextDataFile()
logger.info(f'Data ready for {current=} in {ch=}')
logger.info(f'Data saved to {fn=}')
trEIT.save(fn)
central_frequency = 6.83468e9
frequency_span = 2500e3
dwellTime=0.1
Np=1000
Nsweeps=5
eitVsCurrent(ch=1)
eitVsCurrent(ch=2)
eitVsCurrent(ch=3)
|