diff options
Diffstat (limited to 'examples/lock_eit.py')
-rw-r--r-- | examples/lock_eit.py | 18 |
1 files changed, 9 insertions, 9 deletions
diff --git a/examples/lock_eit.py b/examples/lock_eit.py index 2fbc249..4f88a34 100644 --- a/examples/lock_eit.py +++ b/examples/lock_eit.py @@ -136,7 +136,7 @@ async def initial_lock_to_eit(apparatus, extra_tags={}): ai["pid"].reset() ai["pid"].setEnable(True) apparatus.runStatus = True - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=50)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=50)) async def calibratingLockin(apparatus, extra_tags={}): @@ -148,14 +148,14 @@ async def calibratingLockin(apparatus, extra_tags={}): ai["pid"].setEnable(False) ai["pid"].reset() apparatus.gui_log.setTraces(initLog(extra_tags=extra_tags)) - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) fr0 = ai["rfgen"].getFreqFixed() df = 10 ai["pid"].setEnable(False) ai["pid"].reset() apparatus.setRFreq(fr0 + df) - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) apparatus.setRFreq(fr0) log = apparatus.gui_log.traces @@ -191,10 +191,10 @@ async def responseToChangeOfBfieldControlVoltage(apparatus, extra_tags={}): # initial lock ai["pid"].setEnable(True) ai["pid"].reset() - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) # this is for the money lock - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=30)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=30)) fr0 = ai["rfgen"].getFreqFixed() @@ -202,7 +202,7 @@ async def responseToChangeOfBfieldControlVoltage(apparatus, extra_tags={}): ai["lockin"].AuxOut1 = 0 ai["pid"].setEnable(True) ai["pid"].reset() - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=30)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=30)) fr1 = ai["rfgen"].getFreqFixed() # log = apparatus.gui_log.traces @@ -219,7 +219,7 @@ async def responseToChangeOfBfieldControlVoltage(apparatus, extra_tags={}): ai["lockin"].AuxOut1 = 0 ai["pid"].setEnable(True) ai["pid"].reset() - res = await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) + await asyncio.gather(feedbackLoop(apparatus, nsteps=20)) return float(slope) @@ -423,11 +423,11 @@ async def main(): await initial_lock_to_eit(apparatus, extra_tags=extra_tags) - lockin_slope = await calibratingLockin(apparatus, extra_tags=extra_tags) + await calibratingLockin(apparatus, extra_tags=extra_tags) instruments_config.container = getConfig(apparatus) instruments_config.display_container_dictionary() - B_response = await responseToChangeOfBfieldControlVoltage( + await responseToChangeOfBfieldControlVoltage( apparatus, extra_tags=extra_tags ) instruments_config.container = getConfig(apparatus) |