aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--qolab/hardware/multimeter/__init__.py84
-rw-r--r--qolab/hardware/multimeter/_basic.py84
-rw-r--r--qolab/hardware/multimeter/bk_5491.py2
-rw-r--r--qolab/hardware/multimeter/hp_34401.py2
4 files changed, 90 insertions, 82 deletions
diff --git a/qolab/hardware/multimeter/__init__.py b/qolab/hardware/multimeter/__init__.py
index 20fd1e6..bf8871d 100644
--- a/qolab/hardware/multimeter/__init__.py
+++ b/qolab/hardware/multimeter/__init__.py
@@ -1,82 +1,6 @@
-from qolab.hardware.scpi import SCPIinstr
-from qolab.hardware.basic import BasicInstrument
+"""Multimeters."""
+from .bk_5491 import BK_5491
+from .hp_34401 import HP_34401
-class Multimeter(BasicInstrument):
- """
- Multimeter basic class.
-
- Intended to be part of the hardware aware class.
- """
-
- def __init__(self, *args, **kwds):
- BasicInstrument.__init__(self, *args, **kwds)
- self.config["Device type"] = "Multimeter"
- self.config["Device model"] = (
- "Generic Multimeter generator Without Hardware interface"
- )
- self.config["FnamePrefix"] = "Multimeter"
- self.config["Device model"] = "Generic Multimeter Without Hardware interface"
- self.config["FnamePrefix"] = "multimeter"
- self.deviceProperties.update({})
-
- # Minimal set of methods to be implemented.
- def getVdc(self):
- """Report DC Voltage"""
- print("getVdc is not implemented")
- return None
-
- def getVac(self):
- """Report AC Voltage"""
- print("getVac is not implemented")
- return None
-
- def getAdc(self):
- """Report DC Current"""
- print("getAdc is not implemented")
- return None
-
- def getAac(self):
- """Report AC Current"""
- print("getAac is not implemented")
- return None
-
- def getResistance(self):
- """Report Resistance"""
- print("getResistance is not implemented")
- return None
-
- def getResistance4Wires(self):
- """Report Resistance with 4 wire method"""
- print("getResistance4Wires is not implemented")
- return None
-
- def getDiode(self):
- """Report Diode Voltage drop"""
- print("getDiode is not implemented")
- return None
-
- def getFreq(self):
- """Report Frequency"""
- print("getFreq is not implemented")
- return None
-
-
-class MultimeterSCPI(SCPIinstr, Multimeter):
- """
- SCPI enabled basic multimeter.
-
- Intended to be part of the hardware aware class.
-
- Example
- -------
- >>> rm = pyvisa.ResourceManager()
- >>> MultimeterSCPI(rm.open_resource('TCPIP::192.168.0.2::INSTR'))
- """
-
- pass
-
- def __init__(self, resource, *args, **kwds):
- SCPIinstr.__init__(self, resource)
- Multimeter.__init__(self, *args, **kwds)
- self.config["DeviceId"] = str.strip(self.idn)
+__all__ = ["BK_5491", "HP_34401"]
diff --git a/qolab/hardware/multimeter/_basic.py b/qolab/hardware/multimeter/_basic.py
new file mode 100644
index 0000000..a8e5fac
--- /dev/null
+++ b/qolab/hardware/multimeter/_basic.py
@@ -0,0 +1,84 @@
+"""Basic multimeter classes to be included in hardware aware classes."""
+
+from qolab.hardware.scpi import SCPIinstr
+from qolab.hardware.basic import BasicInstrument
+
+
+class Multimeter(BasicInstrument):
+ """
+ Multimeter basic class.
+
+ Intended to be part of the hardware aware class.
+ """
+
+ def __init__(self, *args, **kwds):
+ BasicInstrument.__init__(self, *args, **kwds)
+ self.config["Device type"] = "Multimeter"
+ self.config["Device model"] = (
+ "Generic Multimeter generator Without Hardware interface"
+ )
+ self.config["FnamePrefix"] = "Multimeter"
+ self.config["Device model"] = "Generic Multimeter Without Hardware interface"
+ self.config["FnamePrefix"] = "multimeter"
+ self.deviceProperties.update({})
+
+ # Minimal set of methods to be implemented.
+ def getVdc(self):
+ """Report DC Voltage"""
+ print("getVdc is not implemented")
+ return None
+
+ def getVac(self):
+ """Report AC Voltage"""
+ print("getVac is not implemented")
+ return None
+
+ def getAdc(self):
+ """Report DC Current"""
+ print("getAdc is not implemented")
+ return None
+
+ def getAac(self):
+ """Report AC Current"""
+ print("getAac is not implemented")
+ return None
+
+ def getResistance(self):
+ """Report Resistance"""
+ print("getResistance is not implemented")
+ return None
+
+ def getResistance4Wires(self):
+ """Report Resistance with 4 wire method"""
+ print("getResistance4Wires is not implemented")
+ return None
+
+ def getDiode(self):
+ """Report Diode Voltage drop"""
+ print("getDiode is not implemented")
+ return None
+
+ def getFreq(self):
+ """Report Frequency"""
+ print("getFreq is not implemented")
+ return None
+
+
+class MultimeterSCPI(SCPIinstr, Multimeter):
+ """
+ SCPI enabled basic multimeter.
+
+ Intended to be part of the hardware aware class.
+
+ Example
+ -------
+ >>> rm = pyvisa.ResourceManager()
+ >>> MultimeterSCPI(rm.open_resource('TCPIP::192.168.0.2::INSTR'))
+ """
+
+ pass
+
+ def __init__(self, resource, *args, **kwds):
+ SCPIinstr.__init__(self, resource)
+ Multimeter.__init__(self, *args, **kwds)
+ self.config["DeviceId"] = str.strip(self.idn)
diff --git a/qolab/hardware/multimeter/bk_5491.py b/qolab/hardware/multimeter/bk_5491.py
index 34d3725..4cdfd2d 100644
--- a/qolab/hardware/multimeter/bk_5491.py
+++ b/qolab/hardware/multimeter/bk_5491.py
@@ -1,5 +1,5 @@
from qolab.hardware.basic import BasicInstrument
-from qolab.hardware.multimeter import Multimeter
+from ._basic import Multimeter
from pyvisa import constants as pyvisa_constants
import time
diff --git a/qolab/hardware/multimeter/hp_34401.py b/qolab/hardware/multimeter/hp_34401.py
index 673c81a..2e586f1 100644
--- a/qolab/hardware/multimeter/hp_34401.py
+++ b/qolab/hardware/multimeter/hp_34401.py
@@ -1,5 +1,5 @@
from qolab.hardware.basic import BasicInstrument
-from qolab.hardware.multimeter import MultimeterSCPI
+from ._baskic import MultimeterSCPI
from qolab.hardware.scpi import SCPI_PROPERTY
from pyvisa import constants as pyvisa_constants
import time